MISMANAGEMENT AND MALADMINISTRATION IN U.M.C HAVE MADE THE WATER
SUPPLY SYSTEM A TOTAL FAILURE AND RUNS ON TRIAL AND ERROR BASIS ONLY.
1.
Lack of required necessary technical staff from
Executive Engineer to skilled labour like fitters and plumbers.
2.
Rain Water Harvesting not even implemented in
the UMC offices Parks and schools.
3.
Underground water is neither monitored nor
utilized for non-potable purposes. No regulations, policies or control over the
private bore wells Even no hydrogeological map prepared in the department.
4.
Two rivers are flowing in township which could have
been the source of water but no action is taken to revive them and make them
pollution free.
5.
The obsolete distribution system lines are not
disconnected even after laying the new scheme.
6.
There is no metering system implemented for
house connections.
7.
There is no separate unit for leak detection and
leak repair cell in UMC.
8.
No record drawings of water supply lines laid
and running are maintained showing the technical details in any water supply section
of the UMC.
9.
The consumers take new lines and discard the old
and obsolete connection lines the boring points are not plugged resulting in
huge waste of water.
10.
Consumer connections are allowed and taken from
side drains and nallas from distribution line to consumer point and rusting of
pipes takes place resulting in leakages and contamination of water.
11.
The estimates on trial and error basis are
prepared passed and executed with inferior quality of G.I pipes without preparing
and sanctioning any technical design as no data is available with the department
of existing system in form of drawings and mapping.
12.
The connections are directly taken from the
transmission lines which are only meant for transfer of water from source to refill
the water tanks Hence tanks does not get filled and people in that area are
facing scarcity of water.
13.
There is no computerisation system in water
supply department for operations and maintenance of the system.
14.
There is no integrated system to track the
complaint and compliance of leakages reported and repaired in time bound
manner. Even freely available mobile applications are not used by U.M.C to
rectify and repair the leakages reported by staff and public.
15.
Even though water supply from M.I.DC is more than
the required by whole township but due to 40% leakages which can be curbed , Zoning
system is not implemented due to interconnections of lines with surrounding
zones in the old distribution system which are not disconnected. Resulting in
uneven distribution and creating scarcity of water in the areas which are at
high levels are at end points from the source of water.